Position:home > News > Product display of Wenzhou Fangyuan Instrument Co., Ltd: FFZ412A far infrared emissivity tester

Product display of Wenzhou Fangyuan Instrument Co., Ltd: FFZ412A far infrared emissivity tester

 

    Solar rays can be roughly divided into visible light and invisible light.  Visible light refracts the light (spectrum) of purple, blue, green, green, yellow, orange and red through the prism.  The light outside the red light is called infrared light, or infrared light, when the wavelength in the spectrum ranges from 0.75 to 1000 microns.  Infrared ray belongs to the category of electromagnetic wave and is an electromagnetic wave with strong thermal effect.  The wavelength range of infrared rays is very wide. People divide infrared rays in different wavelength ranges into near infrared, mid-infrared and far infrared regions. Electromagnetic waves with corresponding wavelengths are called near infrared, mid-infrared and far infrared.  Far infrared ray is a kind of ray. As far infrared ray is close to the vibration frequency of cells and molecules in the human body, it is beneficial to eliminate blood vessel hoarding and harmful substances in the body after penetrating into the body, and has the functions of activating tissue cells, preventing aging and strengthening immune system.  Any environment above zero degree (273.15 ℃) emits infrared rays of varying degrees everywhere, which is called heat ray in modern physics.  The indexes of far infrared radiation energy strength include radiation power and radiance, but in practical application, emissivity is often used to characterize it.  Far infrared emissivity refers to the ratio of the far infrared radiation intensity of the test sample to the far infrared radiation intensity of the black body at a certain temperature within a wavelength interval.  In recent years, more and more fabrics with far infrared properties have been marked on the market.  But the performance varies greatly.  Wenzhou fangyuan instrument co., ltd. has developed FFZ412A far infrared emissivity tester according to the requirements of  GB/T301272013 Textile Far Infrared Performance Testing And Evaluation, which can conveniently provide reliable and relatively high data for the research and development and testing of these products.

    Uses: Used for measuring far infrared properties of various textile products, including fibers, yarns, fabrics, nonwovens and their products by far infrared emissivity method.  Compliance with standards: GB/T30127 4.1 Determination of Far Infrared Emissivity, etc.

 

    Instrument characteristics:

    1. It adopts touch screen control and display and menu mode of operation, which is as convenient as a smart phone.

    2. The core control component is a multi-functional motherboard composed of 32 - bit MCU of Italian company.

    3. The surface of the instrument is sprayed with a relatively good electrostatic spraying process, which is clean and beautiful.

    4. Using advanced optical modulation technology, the measurement is not affected by surface radiation and environmental radiation of the measured object.

    5. In order to ensure the measurement accuracy of the instrument, in the design of the instrument, a special diffuse reflection (DR) compensation channel is added in addition to the mirror reflection (MR) probe channel, taking into account the measurement error caused by diffuse reflection of the sample.

    6. Phase - locked technology and microelectronic technology are adopted in signal and electronic processing technology, which can better detect weak signals and further improve the performance of the instrument.

    7. The measured sample will not be damaged during the measurement process.

    8. With RS232 interface, it is convenient to operate and control the instrument on the computer.

 

    Technical parameters:

    1. Measurement band: 514 μ m.

    2. Emissivity measurement range: 0.1 ~ 0.99.

    3. Indication error: ±0.02ε>0.50

    4. Measurement accuracy: 0.1FS.

    5. Measurement temperature: normal temperature (RT~50).

    6. Diameter of test hot plate: 60 mm ~ 80 mm.

    7. sample diameter: 60 mm.

    8. Standard Blackbody Plate: 0.95 Blackbody Plate

 

    Scope of supply:

    1. One host computer;

    2. One CD of online software;

    3, A product certificate;

    4. A copy of the product instruction manual;