APPLICATION:
To test the ability of metal conductor insulated bundled cables to inhibit flame spread under specified conditions.
STANDARDS:
IEC 60332-3-10, IEC 60332 - 3 - 21 ~ 25, GB/T18380.31~36 ~ 36, etc.
Technical parameters:
1. Size of stainless steel test box: 1000±100 ( W ) × 2000 100 ( D ) × 4000±100 ( H ) mm
2. Air inlet of lower front half of box body: 800±20 ( W ) × 400±10 ( D )
3. Vent at the top of the box: 300±30(W)×1000±100(D)mm
4. Box observation window: Refractory glass
5. Dimensions of steel ladder for testing ( vertical ): 500(W)×3500(H)mm
6. Wide steel ladder size: 800(W) ×3500(H)mm
7. Combustion surface size: (L)257×(W) 4.5mm
8. Inner wall temperature: 5 ℃ ~ 40 ℃
9. Propane flow range: 77.7±4.8L/min
10. Air flow range: 13.5±0.5L/min ( provided by air compressor users ).
11. The heat source is a belt-type propane burner burner with Venturi mixer, and the hole center distance is 3.2 mm.
12. A flame stop cylinder is installed to prevent propane gas from tempering.
13. The computer automatically records all control and test conditions.